Bind error

Bind error SearchSearch
Author Message
sarath kumar
New member
Username: Sarathkumar

Post Number: 1
Registered: 09-2006
Posted on Wednesday, September 06, 2006 - 03:16 pm:   

Hi,
i am trying out the trial version of now sms with an smsc simulator from logica. when i try to configure the SMSC conncetion i am getting the below error:
Unable to login to SMPP server with specified parameters,
ERROR: Invalid username/system id

and the smsc simulator says:
> 07:15:37 [sys] new connection accepted
07:15:37 [] client request: (bindreq: (pdu: 44 9 0 1) sarath sarath Logica 52 (addrrang: 1 1 10*) )
07:15:37 [] not authenticated sarath -- user not found
07:15:37 [] server response: (bindresp: (pdu: 0 80000009 f 1) )


Later tried to connect the smsc simulator with the logica's java test application (client). i am getting the same error, the keyed in values for the client application are like below:

Asynchronous/Synchronnous Session? (a/s) [a]
Transmitter/Receiver/Transciever (t/r/tr) [tr]
IP address of SMSC [10.238.115.223]
Port number [11000]
Your system ID [sarath] sarath
Your password [sarath] sarath
Bind request (bindreq: (pdu: 0 9 0 [1]) sarath sarath Logica 52 (addrrang: 1 1 10*) )
Bind response (bindresp: (pdu: 16 80000009 f 1) )

i feel the problem is with the system ID and password, could any body suggest me what the values should i provide here & how/where i will get the same (currently i am using username & password).

Thanks in advance,

Sarath.
Bryce Norwood - NowSMS Support
Board Administrator
Username: Bryce

Post Number: 6517
Registered: 10-2002
Posted on Friday, September 15, 2006 - 08:03 pm:   

In NowSMS, what we refer to as "username" is what Logica refers to as "system id".

It sounds like "sarath" is not defined as a user account (or system id account) in your installation of the Logica simulator. Refer to the documentation for the simulator for how to add user accounts to the simulator.

(Hint: There is a file named users.txt)